Determination of Glucose by Flow Injection Analysis with Amperometric Detection at Fe(III)-(tris(3,5-dimethyl-1-pyrazolyl)borate)2 Modified Electrodes

Authors

  • Prisciliano Hernández Universidad Autónoma del Estado de Hidalgo
  • José A. Rodríguez Universidad Autónoma del Estado de Hidalgo
  • Verónica Salazar Universidad Autónoma del Estado de Hidalgo
  • Giaan A. Álvarez-Romero Universidad Autónoma del Estado de Hidalgo
  • Simplicio González-Montiel Universidad Autónoma del Estado de Hidalgo
  • Yolanda Castrillejo Universidad de Valladolid.

DOI:

https://doi.org/10.29356/jmcs.v55i2.842

Keywords:

Glucose, Hydrogen peroxide, Flow injection system.

Abstract

A modified screen printed electrode with [Fe(tris(3,5-dimethyl-1-pyrazolyl)borate)2]+[FeCl4]-, installed as part of a flow injection system, was used as an amperometric detector to determine hydrogen peroxide and glucose after on-line reaction with glucose oxidase. The influence of experimental variables on sensitivity, such as the flow rate, injection volume and reaction coil length, was evaluated using a two-level factorial experimental design. Under optimal conditions, detection limits of 15 μM and 0.5 mM for H2O2 and glucose, respectively, were obtained. A sampling rate of 60 determinations h-1 was achieved; the relative standard deviation of analytical measurements was <5.0%. The method was validated by comparing the obtained results with those provided by the enzymatic spectrophotometric method; no significant differences were observed (p < 0.05).

Downloads

Download data is not yet available.

Author Biographies

Prisciliano Hernández, Universidad Autónoma del Estado de Hidalgo

Centro de Investigaciones Químicas

José A. Rodríguez, Universidad Autónoma del Estado de Hidalgo

Centro de Investigaciones Químicas

Verónica Salazar, Universidad Autónoma del Estado de Hidalgo

Centro de Investigaciones Químicas

Giaan A. Álvarez-Romero, Universidad Autónoma del Estado de Hidalgo

Centro de Investigaciones Químicas

Simplicio González-Montiel, Universidad Autónoma del Estado de Hidalgo

Centro de Investigaciones Químicas

Yolanda Castrillejo, Universidad de Valladolid.

Facultad de Ciencias. Departamento de Química Analítica

References

Baynes, J. W.; Dominiczak, M. H. Bioquímica Médica. Elsevier, España, 2005, 277.

Cipolla, M. J.; Godfrey, J. A. Transl. Stroke Res. 2010, 1, 127-134.

Wen, Z.; Ci, S.; Li, J. J. Phys. Chem. 2009, C 113, 13482-13487.

Wang, W.; Wang, F.; Yao, Y.; Hu, S.; Shiu, K. K. Electrochim. Acta 2010, 55, 7055-7060.

Kong, T.; Chen, Y.; Zhang, K.; Wang, Z.; Wang, X. Sensors Actuators B 2009, 138, 344-350.

Trinder, P. Ann. Clin. Biochem. 1969, 6, 24-25

Sapre, A. G.; Bedekar, A.; Deshpande, A. V.; Lali, A. M. Biotechnol. Lett. 2000, 22, 569-573.

JieHua, L.; Hui, Z.; ShuSheng, Z. Sci. China Ser B 2009, 52, 196-202.

Luo, Y.; Liu, H.; Rui, Q.; Tian, Y. Anal. Chem. 2009, 81, 3035-3041.

Hsu, C. T.; Chung, H. H.; Tsai, D. M.; Fang, M. Y.; Hsiao, H. C.; Zen, J. M. Anal. Chem. 2009, 81, 515–518.

Nenkova, R.; Ivanova, D.; Vladimirova, J.; Godjervargova, T. Sensors Actuators B 2010, 148, 59-65.

Chaubey, A.; Malhotra, B.D. Biosens. Bioelectron. 2002, 17, 441-456.

Merchant, S. A.; Tran, T. O.; Meredith, M. T.; Cline, T. C.; Glatzhofer, D. T.; Schmidtke, D. W. Langmuir 2009, 25, 7736–7742.

Heller, A.; Feldman, B. Chem. Rev. 2008, 108, 2482-2505.

Wang, Y.; He, Q.; Dong, Y.; Chen, H. Sensors Actuators B 2010, 145, 553-560.

Bosque-Sendra, J.M.; Gamiz-Gracia, L.; Garcia-Campaña, A.M. Anal. Bioanal. Chem. 2003, 377, 863-874.

Trofimenko, S. Chem. Rev. 1993, 93, 943-980.

Courjean, O.; Mano, N. J. Biotechnol. 2011, 151, 122-129

Long, G. L.; Winefordner, J. D. Anal. Chem. 1983, 55, 712A-724A.

Lei, C.; Deng, J. Anal. Chem. 1996, 68, 3344-3349

Kotzian, P.; Brazdilova, P.; Kalcher, K.; Vytras, K. Anal. Lett. 2005, 38, 1099-1113.

Tarley, C. R. T.; Silveira, G.; Santos, W. M. L.; Matos, G. D.; Silva, E. G. P.; Bezerra, M. A.; Miro, M.; Ferreira, S. L. C. Microchem. J. 2009, 92, 58-67

Ruzicka, J.; Hansen, E.H. Flow Injection Analysis. Wiley, 1988.

Massart, D. L.; Vandeginste, B. G. M.; Buydens, L. M. C.; De Jong, S.; Lewi, P. J.; Smeyers-Verbeke, J. Handbook of Chemometrics and Qualimetrics: Part A. Ed. Elsevier Science, 1997.

Sheets, J. R.; Schultz, F. A. Polyhedron 2004, 23, 1037-1043.

Downloads

Published

2019-04-22

Issue

Section

Regular Articles