Determination of Glucose by Flow Injection Analysis with Amperometric Detection at Fe(III)-(tris(3,5-dimethyl-1-pyrazolyl)borate)2 Modified Electrodes
DOI:
https://doi.org/10.29356/jmcs.v55i2.842Keywords:
Glucose, Hydrogen peroxide, Flow injection system.Abstract
A modified screen printed electrode with [Fe(tris(3,5-dimethyl-1-pyrazolyl)borate)2]+[FeCl4]-, installed as part of a flow injection system, was used as an amperometric detector to determine hydrogen peroxide and glucose after on-line reaction with glucose oxidase. The influence of experimental variables on sensitivity, such as the flow rate, injection volume and reaction coil length, was evaluated using a two-level factorial experimental design. Under optimal conditions, detection limits of 15 μM and 0.5 mM for H2O2 and glucose, respectively, were obtained. A sampling rate of 60 determinations h-1 was achieved; the relative standard deviation of analytical measurements was <5.0%. The method was validated by comparing the obtained results with those provided by the enzymatic spectrophotometric method; no significant differences were observed (p < 0.05).
Downloads
References
Baynes, J. W.; Dominiczak, M. H. Bioquímica Médica. Elsevier, España, 2005, 277.
Cipolla, M. J.; Godfrey, J. A. Transl. Stroke Res. 2010, 1, 127-134.
Wen, Z.; Ci, S.; Li, J. J. Phys. Chem. 2009, C 113, 13482-13487.
Wang, W.; Wang, F.; Yao, Y.; Hu, S.; Shiu, K. K. Electrochim. Acta 2010, 55, 7055-7060.
Kong, T.; Chen, Y.; Zhang, K.; Wang, Z.; Wang, X. Sensors Actuators B 2009, 138, 344-350.
Trinder, P. Ann. Clin. Biochem. 1969, 6, 24-25
Sapre, A. G.; Bedekar, A.; Deshpande, A. V.; Lali, A. M. Biotechnol. Lett. 2000, 22, 569-573.
JieHua, L.; Hui, Z.; ShuSheng, Z. Sci. China Ser B 2009, 52, 196-202.
Luo, Y.; Liu, H.; Rui, Q.; Tian, Y. Anal. Chem. 2009, 81, 3035-3041.
Hsu, C. T.; Chung, H. H.; Tsai, D. M.; Fang, M. Y.; Hsiao, H. C.; Zen, J. M. Anal. Chem. 2009, 81, 515–518.
Nenkova, R.; Ivanova, D.; Vladimirova, J.; Godjervargova, T. Sensors Actuators B 2010, 148, 59-65.
Chaubey, A.; Malhotra, B.D. Biosens. Bioelectron. 2002, 17, 441-456.
Merchant, S. A.; Tran, T. O.; Meredith, M. T.; Cline, T. C.; Glatzhofer, D. T.; Schmidtke, D. W. Langmuir 2009, 25, 7736–7742.
Heller, A.; Feldman, B. Chem. Rev. 2008, 108, 2482-2505.
Wang, Y.; He, Q.; Dong, Y.; Chen, H. Sensors Actuators B 2010, 145, 553-560.
Bosque-Sendra, J.M.; Gamiz-Gracia, L.; Garcia-Campaña, A.M. Anal. Bioanal. Chem. 2003, 377, 863-874.
Trofimenko, S. Chem. Rev. 1993, 93, 943-980.
Courjean, O.; Mano, N. J. Biotechnol. 2011, 151, 122-129
Long, G. L.; Winefordner, J. D. Anal. Chem. 1983, 55, 712A-724A.
Lei, C.; Deng, J. Anal. Chem. 1996, 68, 3344-3349
Kotzian, P.; Brazdilova, P.; Kalcher, K.; Vytras, K. Anal. Lett. 2005, 38, 1099-1113.
Tarley, C. R. T.; Silveira, G.; Santos, W. M. L.; Matos, G. D.; Silva, E. G. P.; Bezerra, M. A.; Miro, M.; Ferreira, S. L. C. Microchem. J. 2009, 92, 58-67
Ruzicka, J.; Hansen, E.H. Flow Injection Analysis. Wiley, 1988.
Massart, D. L.; Vandeginste, B. G. M.; Buydens, L. M. C.; De Jong, S.; Lewi, P. J.; Smeyers-Verbeke, J. Handbook of Chemometrics and Qualimetrics: Part A. Ed. Elsevier Science, 1997.
Sheets, J. R.; Schultz, F. A. Polyhedron 2004, 23, 1037-1043.
Downloads
Published
Issue
Section
License
Authors who publish with this journal agree to the following terms:
- Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
- Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.